All posts by Steve

stmtrap-up2000

 

Ultraprobe® 2000 Accessories

The following accessories are typically used with the Ultraprobe® 2000.

up2000-holster-new HTS-2: HOLSTER SET
One for the Ultraprobe pistol, module and headphones, the other for accessories. Keeps hands free for walking routes and climbing up and down ladders.
lrm-long-range-module_200x126 LRM-2: LONG RANGE MODULE
Advanced technology from UE Systems and National Aeronautics and Space Administration brings distant leaks and electrical transmissions close-up. (like an ultrasonic telescope)
uwc2000j_200x159 UWC-2: ULTRASONIC WAVE FORM CONCENTRATOR (PARABOLIC DISH
The UWC doubles the detection range of standard scanning modules and pinpoints ultrasonic leaks & electric emissions at great distances.
CFM-CU-sml-lt-199x123 CFM-2: CLO SE FOCUS MODULE
A specialized module to help locate LOW LEVEL pressure and vacuum leaks.
exc2 EXC-2: MODULE INTERCONNECTION CABLE
Shielded cable, works with either module for hard to reach areas. Standard length: 8? (2.4M). Lengths up to 50 ft. are available.
telebend-bent_200x87 TFSM-2 TELESCOPING & FLEXIBLE SCANNING MODULE with RAM (Remote Access Module)
Extend and Bend this probe to odd angles to locate sound sources in hard to reach areas.
(up to 56 in / 1.4 m)
u-bend-fsm-up2000_200x134 FSM-2: FLEXIBLE SCANNING MODULE
Bend this probe to odd angles to locate sound sources in hard to reach areas.
wtg-1 WTG-2SP: WARBLE PIPE TONE GENERATOR
For leak detection without pressure or vacuum. Heat exchangers, tanks with small openings or pipe sections can be quickly flooded with ultrasound for leak testing.
ufmtg-1 UFMTG 1991: MULTI-DIRECTIONAL TONE GENERATOR
This extremely powerful ultrasonic transmitter contains a multiple array of four transducers that produce UE SYSTEMS patented warble tone to cover a circular pattern of 360°.

Ultraprobe 2000 specifications

 

Ultraprobe 2000  Specifications are as follows:

CONSTRUCTION: Hand held metered pistol type made with anodized aluminum and ABS plastic

FREQUENCY RESPONSE: Detect ultrasonic frequencies between 20 kHz and 100kHz, continuously variable. Frequencies are converted to 100 Hz to 3 kHz audio.

PROBES:

Scanning Module: patented TRISONIC plug-in type consisting of a phased array of multiple transducers for airborne ultrasound. This probe is shielded against RF interface.

Rubber Focusing Probe (flexible) slips over scanning module to concentrate conical directivity and to shield reception of stray ultrasound. Also fits over Stethoscope Module to shield against high ambient ultrasound while unit is at maximum sensitivity.

Stethoscope Module: plug-in type, insulated probe with RF shielding; 4 1/2″ (11.4 cm) long steel probe tip, conically shaped for uniform surface contact. Probe tip is interchangeable. Stethoscope Extension Kit: 3 piece, segmented metal rods to increase stethoscope contact range 20″ (50.8.cm) and 31″ (76.2 cm).

TRANSMITTER: Patented warble tone transmission

HEADSET: Noise isolating type: double headset wired monophonic, impedance, 16 ohms. Over 23 dB of noise attenuation. Meets or exceeds ANSI specification and OSHA standards.

INDICATORS: Ballistic output meter: linear calibration scale of 0-100 for logging relative measurements. Meter is accurate 1% throughout entire scale. Low level Battery LED indicator for main housing internal power supply.

BATTERIES: Self contained nickel-cadmium rechargeable. RECHARGING SYSTEM: Standard 110V. Also available in 220V.

FEATURES:

  • Frequency tuning adjustment dial: Scale 20-100 kHz with “fixed band” positions for ultra-narrow frequency response.
  • Bi-Modal Meter Switch for logarithmic and linear meter scale adjustments.
  • Optional auxiliary mode selection for chart recorder output: 0 – 50 mV, Precision 10 turn adjustment dial with numerically calibrated sensitivity increments for finite gain adjustment.
  • Sensitivity Control, A 10 turn numerically calibrated adjustable potentiometer. Spring loaded trigger switch.

OVER-ALL SIZE: Complete kit in Zero Haliburton aluminum carrying case: 15″ x 22″ x 7″ (38.1 x 55.9 x 17.8 cm). Pistol unit 2 lbs (.9kg). Complete carrying case: 14 lbs (6.4 kg).

SENSITIVITY: Detects .005″ (.127 mm) dia. leak @ 5 psi (.34 bar) at a distance of 50 ft
(15.24 m).

THRESHOLD*: 1 X 10-² 1 X 10-³ std. cc/sec. freon

WARRANTY: 5 Years parts/labor

*depends on configuration

ULTRAPROBE 2000 KIT: Meets and exceeds ASTM E1002-93 requirements for Leak Detection.

GOVERNMENT CODES
NSN: 6635-01-156-3927
FSCM (CAGE) Code: 59202

Table of Allowance #s:
788, 404, 576, 583, 607
Covered by one or more of the following patents: 4416145, EP015115, 502674183

Factory Mutual System Approved

Intrinsically Safe, Class 1, Division I, Groups A, B, C & D

American Buerau of Shipping (ABS) TYPE APPROVAL 95-NY-166-X

UE Systems is committed to continual product improvement therefore Ultraprobe 2000 specifications are subject to change without notice. Warranty details are available by request.

up2000-kit-w-bkgd

 

Ultraprobe® 2000 Ultrasonic Detection Kit

Complete with everything you need to for accurate route inspection, the Ultraprobe® 2000 kit includes:

ULTRAPROBE housing with Metered Pistol Grip, Ballistic Meter, Frequency Tuning Dial, Ten Turn Potentiometer, Numerically Calibrated Sensitivity Dial with Selection Lock, Bi-Modal Meter Selector switch, battery, battery indicator light, battery recharger receptacle and head set receptacle.

  • Trisonic scanning Module for locating airborne ultrasound such as pressure, vacuum and electrical leakage.
  • Rubber Focusing Probe for narrowing reception band of Scanning Module and for blocking out ambient ultrasound.
  • Stethoscope (contact type) Probe for monitoring internally generated ultrasound such as in bearings, steam traps and valves.
  • Deluxe Industrial noise reducing Headset.
  • Video Training Tape Program
  • Extension Probe Kit to increase Stethoscope contact range to 31 inches.
  • Warble Tone Generator with amplitude selection switch for use in Tone Test method.
  • Battery Recharge Kit for main housing and Warble Tone Generator.
  • Zero Halliburton aluminum carrying case

FACTORY MUTUAL RATED

  • Intrinsically Safe
  • Class 1, Division 1, Groups A, B, C & D
  • Exceeds ASTM-1002-05
  • Standards for ultrasonic leak detection
  • CE rated
  • EX Rated

 

comp-air-up100

 

Ultraprobe® 100 Instrument Accessories

 

lr-rubber-focus-adapter-up100_199x117 LRM-1: LONG RANGE MODULE
Scan for leaks at a distance. Brings distant leaks close-up. This specially designed rubber module fits over the standard scanning module.
teleflex-6-22 TFSM-1: TELESCOPING & FLEXIBLE SCANNING MODULE with RAM (Remote Access Module)
Extend and Bend this probe to odd angles to locate sound sources in hard to reach areas. (up to 56 in / 1.4 m).
up100-holster-new HTS-1: HOLSTER SET
One for the Ultraprobe pistol, module and headphones, the other for accessories. Keeps hands free for walking routes and climbing up and down ladders.
deluxe-headphones_200x134 DHC -2HH: DELUXE HEADSET FOR USE WITH HARDHATS
For use in high noise environments. Acts as hearing protection device. Convenient for use with hard hats. Velcro loop head band adjusts for all sizes: same specs as for standard headphones.
ufmtg UFMTG 1991: MULTI-DIRECTIONAL TONE GENERATOR
This extremely powerful ultrasonic transmitter contains a multiple array of four transducers that produce UE SYSTEMS patented warble tone to cover a circular pattern of 360°.
wtg WTG-2SP: WARBLE PIPE TONE GENERATOR
For leak detection without pressure or vacuum. Heat exchangers, tanks with small openings or pipe sections can be quickly flooded with ultrasound for leak testing.

100-kit

Ultraprobe® 100 Ultrasonic Detection Kit

It’s easy to find the right Ultraprobe 100 for your application

AVAILABLE KITS AND ORDERING INFORMATION

UP100KT: ULTRAPROBE 100 KIT

UP100 pistol housing with LED bar graph meter, 8 position sensitivity selection, low battery indicator, scanning module, rubber focusing probe, stethoscope module, warble tone generator with battery recharger, lightweight foam lined headset, 9 volt alkaline battery (replaceable), cordura/nylon soft pack and comprehensive instruction manual.

UP100SC: ULTRAPROBE 100 STETHOSCOPE / SCANNER KIT

UP100 pistol housing with LED bar graph meter, 8 position sensitivity selection, low battery indicator, scanning module, rubber focusing probe, stethoscope module, lightweight foam lined headset, 9 volt alkaline battery (replaceable), cordura/nylon soft pack and comprehensive instruction manual.

UP100STG: ULTRAPROBE 100 SCANNER / TONE GENERATOR KIT

UP100 pistol housing with LED bar graph meter, 8 position sensitivity selection, low battery indicator, scanning module, rubber focusing probe, warble tone generator with battery recharger, lightweight foam lined headset, 9 volt alkaline battery recharger (replaceable), cordura/nylon soft pack and comprehensive instruction manual.

UP100C: ULTRAPROBE 100 STETHOSCOPE KIT

UP100 pistol housing with LED bar graph meter, 8 position sensitivity selection, low battery indicator, stethoscope module, lightweight foam lined headset, 9 volt alkaline battery (replaceable), cordura/nylon soft pack and comprehensive instruction manual.

UP100S: ULTRAPROBE 100 SCANNER KIT

UP100 pistol housing with LED bar graph meter, 8 position sensitivity selection, low battery indicator, scanning module, rubber focusing probe, lightweight foam lined headset, 9 volt alkaline battery (replaceable), cordura/nylon soft pack and comprehensive instruction manual.

Ultraprobe 100 Specifications

 

Ultraprobe 100 Specifications are as follows

Construction: Handheld ABS pistol type ultrasonic processor, stainless steel sensor enclosures

Circuitry: SMD/Solid State hybrid heterodyne receiver

Frequency Range: 35-45 kHz

Indicator: 10 segment LED bargraph (red)

Sensitivity Selection: 8 position precision attenuation

Power: 9 Volt Alkaline Battery

Low Battery Voltage Indicator: LED

Headset: Noise isolating type: double headset wired monophonic impedance; 16 ohms. Over 23 dB noise attenuation. Meets or exceeds ANSI specification and OSHA standards.

Probes: Scanning Module (SCM-1) Stainless Steel Unisonic (single transducer) piezo electric crystal type; Stethoscope/Contact Module (STM-1) Stainless Steel plug-in type with 5.5? Stainless Steel Waveguide.

Rubber Focusing Probe: Shields stray ultrasonic signals & focuses detected signals.

Transmitter: Patented warble tone transmission

Response Time: 300 m. sec.

Ambient Operating Temperature Range: 32°-120°F(0°-50°C)

Relative Humidity: 10-95% non condensing at up to 86°F(30°C)

Storage Temperature: 0°-130°F (-18°-54°C)

Warranty: One year, parts/labor. (Details available on request)

Dimensions: 5.25″ x 2″ x 8″ (13.3cm x 5cm x 20.3cm)

Weight: 11 oz (.3kg)

Carrying Case: Nylon soft carry case with die cut foam

*In an effort to provide the highest quality, Ultraprobe 100 specifications are subject to change without notice.

Intrinsically safe test equipment is a requirement for workplaces where combustible gasses may be present. Prior to performing an infrared inspection in such areas, it is important to understand the meaning and importance of this requirement.

Experienced thermographers know that image clarity is one of the most important considerations in thermal imaging. For thermal imagers, imager frame rate is an important characteristic that can greatly influence image quality.

Airborne and Structure-borne ultrasound have evolved into a technology that many would consider to be the cornerstone of an effective maintenance and reliability program.

Shipping infrared equipment is a frequent necessity for thermographers. Taking the time to make certain that equipment is adequately insured can help prevent bigger problems in the event of loss or damage.